PAUL Iso-Preheater DN 160 FILTER (350x250x40)

  • Delivery: 20-30 days.
€11.98
Delivery: 20-30 days.
Filtrai1.lt
Reference
K00125

Date sheet

Dimensions (mm)
350x250x40
Delivery of goods
€ 2.90 (free shipping from € 50)
Paul model
PAUL Iso-Preheater DN 160

Filter set suitable for PAUL Iso-Preheater DN160.

Filter G4, which fits in place of the original Paul filter.

PAUL Iso-Preheater DN160 filter specification:

  • Filter dimensions - 350x250x40
  • Made in Lithuania
  • Moisture-proof cardboard frame
  • ECO green
  • Large filtering area
  • Complies with hygiene class VDI6022
  • Corresponds to DIN53438 flammability class
  • Conforms to ISO16980 standard
  • Complies with EN779:2012 standard

Recommendation:

  • It is recommended to change recuperator filters at least 2-3 times a year.

ECO green
Filtrai1.lt filters have "ECO green" properties. The filters are made of recycled and durable materials.

Hygiene standard VDI6022
The filters we sell comply with the ventilation hygiene standard VDI6022. The standard ensures that filter materials do not allow bacteria to breed.

Flammability DIN53438 classification
The filters sold by Filtrai1.lt are tested and have the appropriate flammability classification.

The filters are made using the unique DEEP PLEAT technology.
Thanks to this technology:

  • When corrugating, the material maintains the correct V shape
  • The maximum area of the filter material is used
  • Extends filter life and efficiency

Discount:
Buy 10 sets or more and contact us for a better price

useful information
When and how often should recuperator filters be changed?
Universal instructions for changing recuperator filters
Air filter classes, standards and marking

Reviews

Write your review

PAUL Iso-Preheater DN 160 FILTER (350x250x40)

Filter Type / EN 779ISO 16890>10 µmPM10PM2.5PM1Gas/LOITypical Pollutants
G1ISO Coarse~40%<10%~0%~0%Large dust: sand grains, textile fibers, carpet lint, plant residues, insect parts, etc.
G2ISO Coarse~50%<15%~0%~0%Sawdust, hair, large fabric shreds, paint chips, surface rust particles.
G3ISO Coarse~60%<25%~5%~0%Larger household dust, lint, animal hair, some airborne pollen.
G4ISO Coarse65-75%25-35%10-15%<5%Larger pollen grains, soil and sand impurities, textile fibers.
M5ISO ePM10 ≥50%~80%50–65%20–30%10–15%Most pollen, mold spores, pet dander, typical house dust.
M6ISO ePM10 (60–80%)~90%65–80%30–45%15–25%Construction material dust, concrete and cement powders, ash and other friable material particles.
F7ISO ePM2.5 (50–65%)>90%75–90%50–65%30–45%Some bacteria, smog and tobacco smoke particles, combustion product dust, mold spores, wildfire smoke.
F8ISO ePM2.5 (65–80%)>95%85-95%65–80%45-60%Fine fungal spores, airborne pollutant aerosols and other fine solid particles.
F9ISO ePM1 (80-95 %)>95%>95%>90%80-95%Diesel engine soot, some airborne viruses, transport and industrial fumes, very fine combustion particles, extremely fine dusts and secondary organic aerosols formed from chemical reactions in the atmosphere.

Paul Novus 300 and 450 models use filters measuring approximately 475 × 180 × 50 mm, in G4/G4 or F7/G4 configurations.

Standard Paul Focus 200 filters are 275 × 187 × 20 mm in size and are sold as a supply & exhaust air kit.

Paul Climos F 100 and F 150 DC models use cartridge filters with dimensions of approximately 150 × 250 × 45 mm.

No. The “F“ version stands for enthalpy heat exchanger, but the filter types and dimensions do not change — they are the same as in models without moisture return.

No. Paul filters are not universal — they must be selected precisely according to the specific model and series.

Filter set suitable for PAUL Iso-Preheater DN160.

Filter G4, which fits in place of the original Paul filter.

PAUL Iso-Preheater DN160 filter specification:

  • Filter dimensions - 350x250x40
  • Made in Lithuania
  • Moisture-proof cardboard frame
  • ECO green
  • Large filtering area
  • Complies with hygiene class VDI6022
  • Corresponds to DIN53438 flammability class
  • Conforms to ISO16980 standard
  • Complies with EN779:2012 standard

Recommendation:

  • It is recommended to change recuperator filters at least 2-3 times a year.

ECO green
Filtrai1.lt filters have "ECO green" properties. The filters are made of recycled and durable materials.

Hygiene standard VDI6022
The filters we sell comply with the ventilation hygiene standard VDI6022. The standard ensures that filter materials do not allow bacteria to breed.

Flammability DIN53438 classification
The filters sold by Filtrai1.lt are tested and have the appropriate flammability classification.

The filters are made using the unique DEEP PLEAT technology.
Thanks to this technology:

  • When corrugating, the material maintains the correct V shape
  • The maximum area of the filter material is used
  • Extends filter life and efficiency

Discount:
Buy 10 sets or more and contact us for a better price

useful information
When and how often should recuperator filters be changed?
Universal instructions for changing recuperator filters
Air filter classes, standards and marking

Reviews

Write your review

PAUL Iso-Preheater DN 160 FILTER (350x250x40)

Filter Type / EN 779ISO 16890>10 µmPM10PM2.5PM1Gas/LOITypical Pollutants
G1ISO Coarse~40%<10%~0%~0%Large dust: sand grains, textile fibers, carpet lint, plant residues, insect parts, etc.
G2ISO Coarse~50%<15%~0%~0%Sawdust, hair, large fabric shreds, paint chips, surface rust particles.
G3ISO Coarse~60%<25%~5%~0%Larger household dust, lint, animal hair, some airborne pollen.
G4ISO Coarse65-75%25-35%10-15%<5%Larger pollen grains, soil and sand impurities, textile fibers.
M5ISO ePM10 ≥50%~80%50–65%20–30%10–15%Most pollen, mold spores, pet dander, typical house dust.
M6ISO ePM10 (60–80%)~90%65–80%30–45%15–25%Construction material dust, concrete and cement powders, ash and other friable material particles.
F7ISO ePM2.5 (50–65%)>90%75–90%50–65%30–45%Some bacteria, smog and tobacco smoke particles, combustion product dust, mold spores, wildfire smoke.
F8ISO ePM2.5 (65–80%)>95%85-95%65–80%45-60%Fine fungal spores, airborne pollutant aerosols and other fine solid particles.
F9ISO ePM1 (80-95 %)>95%>95%>90%80-95%Diesel engine soot, some airborne viruses, transport and industrial fumes, very fine combustion particles, extremely fine dusts and secondary organic aerosols formed from chemical reactions in the atmosphere.

Paul Novus 300 and 450 models use filters measuring approximately 475 × 180 × 50 mm, in G4/G4 or F7/G4 configurations.

Standard Paul Focus 200 filters are 275 × 187 × 20 mm in size and are sold as a supply & exhaust air kit.

Paul Climos F 100 and F 150 DC models use cartridge filters with dimensions of approximately 150 × 250 × 45 mm.

No. The “F“ version stands for enthalpy heat exchanger, but the filter types and dimensions do not change — they are the same as in models without moisture return.

No. Paul filters are not universal — they must be selected precisely according to the specific model and series.

lt hxr rule
lt hxr rule2